• 100L Control valve Inlet  Section 3/4 Left Inlet (AC)
    Regular price £96.68
    • All Items Guaranteed
    • Delivery to UK & Ireland

    100L Control valve Inlet Section 3/4 Left Inlet (AC)

    Key Features

    • Section type: left inlet (ac) with pressure relief
    • Port size: 3/4" bsp
    • Compatibility: 100l gs sectional control valve
    • Function: pump inlet and adjustable system relief
    • Relief range (typical): 60 ; 315 bar adjustable
    Regular price £96.68
    • All Items Guaranteed
    • Delivery to UK & Ireland
    • Order by 3pm for Next Day Delivery
  • 100L Control Valve Motor Spool (Type 2)
    Regular price £34.18
    • All Items Guaranteed
    • Delivery to UK & Ireland

    100L Control Valve Motor Spool (Type 2)

    Key Features

    • Spool type: motor spool (type 2)
    • Compatibility: 100l gs sectional working section
    • Spool diameter (family): 20 mm interchangeable spools
    • Intended use: bidirectional hydraulic motor control
    • Options: kits for detent ; stroke limiters ; auxiliary valves
    Regular price £34.18
    • All Items Guaranteed
    • Delivery to UK & Ireland
    • Order by 3pm for Next Day Delivery
  • 80L - 100L-150L - 240L Control Valve  Fixed Port Relief/Anti Cav. 220 bar Type RPHT U220
    Regular price £32.48
    • All Items Guaranteed
    • Delivery to UK & Ireland

    80L - 100L-150L - 240L Control Valve Fixed Port Relief/Anti Cav. 220 bar Type RPHT U220

    Key Features

    • Type: fixed port relief ; anti cavitation (rpht)
    • Setting: 220 bar
    • Compatibility: 80l ; 100l ; 150l ; 240l working port cavities
    • Purpose: limits port pressure spikes and prevents cavitation
    • Other settings: 100 ; 120 ; 140 ; 160 ; 180 ; 200 ; 240 ; 260 bar options
    Regular price £32.48
    • All Items Guaranteed
    • Delivery to UK & Ireland
    • Order by 3pm for Next Day Delivery
  • Electrical plug for 12/24VDC coils EP3/4 kits
    Regular price £1.49
    • All Items Guaranteed
    • Delivery to UK & Ireland

    Electrical plug for 12/24VDC coils EP3/4 kits

    Key Features

    • Connector: DIN 43650-A ; 3 pole + earth
    • Ingress protection: IP65 with gasket
    • Rating: up to 240 vac ; 10 a
    • Use: mates to EP3/EP4 solenoid coils 12 ; 24 vdc
    • Application: hydraulic component
    Regular price £1.49
    • All Items Guaranteed
    • Delivery to UK & Ireland
    • Order by 3pm for Next Day Delivery
  • Adam Hindle

    Sales Director

    I began my engineering career at Stockport College in around 2005, first completing a National Diploma in Electrical Engineering, followed by a Higher National Diploma in Mechanical Engineering. I then progressed to the University of Salford, where I earned a BEng (Hons) degree in Mechanical Engineering.

    After graduating, I started my professional career with Approved Hydraulics. I initially gained a combination of hands-on workshop experience and telephone-based sales experience. In later years, I moved into a full-time sales role and led the new crane and excavator attachments department that the company had recently established.

3/4" - 100Lpm - Sectional Valve Spares

Common Calculations FAQs

Calculating force, speed, pressure, power, and efficiency in hydraulic applications.

How do you calculate actuator speed?

Actuator speed is determined by flow rate and cross-sectional area:

Speed = Flow rate ÷ Area

Flow rate is the volume of fluid delivered (in L/min or GPM).

Area is the cross-sectional area of the actuator piston: π × (diameter ÷ 2)².

How do you calculate cylinder force?

Cylinder force can be calculated using:

Force = Pressure × Area

Pressure is the system pressure (in psi or bar).

Area is the cross-sectional area of the cylinder bore (in square inches or square centimeters).

Area = π × (bore diameter ÷ 2)².

How do you calculate pressure drop across a valve?

Pressure drop can be calculated using the valve flow coefficient (Cv):

Pressure Drop (ΔP) = (Flow Rate)² ÷ (Cv² × Fluid Density)

Flow Rate is the fluid flow (in GPM or L/min).

Cv is the valve flow coefficient.

Fluid Density is the density of the hydraulic fluid.

How do you size an accumulator?

Accumulator sizing considers required flow, pressure, and pre-charge:

Accumulator Volume = Flow Rate × Time ÷ Pressure

This determines how much fluid must be stored to maintain system pressure.

How to convert psi to bar?

Use the conversion factor: 1 bar = 14.5 psi.

To convert psi to bar, divide psi by 14.5.

Example: 200 psi ÷ 14.5 = 13.79 bar.

What is pre-charge pressure in an accumulator?

Pre-charge pressure is the initial gas pressure in the accumulator before fluid enters.

It helps maintain system pressure as the accumulator discharges.

Typically set to 70–80% of system operating pressure.

What is specific gravity of hydraulic fluid?

Specific gravity is the ratio of hydraulic fluid density to water.

A value of 1 means equal density.

Less than 1 means the fluid floats; greater than 1 means it sinks.

What is torque in a hydraulic motor?

Torque is the rotational force produced based on system pressure and motor displacement:

Torque = Pressure × Displacement ÷ 2π

Pressure is the operating system pressure.

Displacement is the volume displaced per revolution (in cubic inches or cubic centimeters).

What unit is hydraulic power measured in?

Hydraulic power is measured in horsepower (HP) or kilowatts (kW).

Hydraulic horsepower can be calculated using:

HP = (Pressure (psi) × Flow rate (GPM)) ÷ 1714.

What’s the relationship between pump speed and flow?

Flow rate is directly proportional to pump speed.

If pump speed doubles, flow rate doubles (assuming constant displacement).

This is important when adjusting flow or selecting a pump for varying speeds.