Shop by product
Hydraulic Rotators & Links
Worm Drives Units & Rotary Manifolds
Excavator & Crane Attachments
Forestry Attachments
Rail Attachments
Demolition Attachments
Subsea Attachments
Tractor Attachments
Wireless Weigh Scales
Timber Processing
Mining & Quarry
Directional Control Valves
Line Mounted Valves
Hydraulic Cylinders
Hydraulic Pumps
Hydraulic Motors
Power Packs
PTO Equipment
Remote Controls
Worm Drives & Rotary Manifolds
Oils & Lubricants
Hydraulic Oil Tanks
Stabiliser Pads & Storage Cages
All Other Equipment
Lever Operated Monoblock Valves
CETOP 3 Spares
Scanreco Spares & Accessories
Scanreco
Hydraulic Oil Tank Spares
Series 200 Standard Double Acting Hydraulic Cylinders
TEC Electric Motors
TEC
OMP OMR Motors
High Torque Hydraulic Motors
CETOP 3 Valves
About
Side Mounted Steel Hydraulic Oil Tanks With Filter (15L-60L)
Key Features
Z80 1/2" Solenoid Control Valves 80LPM 12/24VDC
Normall closed prop. flow control in 2 port 3/8" body -24VDC
GP30 Power Take Off Gear Pumps
Sales Director
I began my engineering career at Stockport College in around 2005, first completing a National Diploma in Electrical Engineering, followed by a Higher National Diploma in Mechanical Engineering. I then progressed to the University of Salford, where I earned a BEng (Hons) degree in Mechanical Engineering.
After graduating, I started my professional career with Approved Hydraulics. I initially gained a combination of hands-on workshop experience and telephone-based sales experience. In later years, I moved into a full-time sales role and led the new crane and excavator attachments department that the company had recently established.
AGRI PTO Gear Box 3:1 ratio for Group 2 or 3 Pumps - Male Shaft
120L 1 Bank Monoblock Valve 3/4" Ported Double Acting Spring Return
Hydraulic Power Pack With Starter 24V DC - 2.0kW - P & T Only - 160bar Preset
Mini Hydraulic Power Packs - Standard P&T - 12V/24V DC - 1.6kW - With Starter Solenoid - 160 Bar
Group 3 Gear Pumps with 1:8 Taper Shaft
80L-100L-150L Control Valve Unloader Valve (ELP) Without Coil (See Coils 20032268 12V or 20032269 for 24V)
Agri PTO Gear Box 3:1 Ratio For GP2 pump - QR Female Connection (Max 10 kW)
Series 610 Top Link Cylinders
Anti-Clockwise Group 2 Tandem Hydraulic Pumps - Front
Inline Pressure Relief Valve 1 1/4" Bsp 150Lpm 350 Bar Max
Double Acting Hydraulic Cylinder 90mm Bore Rams
UNLOADER VALVE & BLOCK FOR 45L GM (N/O) 24V
Unloader Valve Block Assy 3/8" BSP (N/O - ELP) Without Coil - See 20032268 - 12V or 20032269 - 24V
15cc Group 2 Reversible Gear Motor 4 Bolt 1:8 taper 250 Bar WP 3/4" BSP Ports + 1/4" BSP Drain
11cc Group 2 Reversible Gear Motor 4 Bolt 1:8 taper 250 Bar WP 3/4" BSP Ports + 1/4" BSP Drain
FLOW DIVIDER/COMBINER 50/50 In line 3/8" BSP in/out 13-23 lpm
150L Control Valve Working Section Double Acting Spool With Port R/v cavity On Top Face.
CETOP 3 - P to T - A&B Blocked with Manual Lever
Cylinder Seal Kit For DAP8040 cylinder (CEL Cyls Models Only)
Anti-clockwise Group 2 Tandem Hydraulic Pumps - Rear
Discover quality hydra part from Approved Hydraulics, trusted by professionals across construction, transport, forestry, agriculture and industrial sectors. Built for demanding working environments, our range offers dependable performance, durable construction and trusted reliability. Browse related products including lever operated monoblock valves, cetop 3 spares, scanreco spares accessories, scanreco to find the right solution for your hydraulic system. With fast UK delivery and expert technical support, Approved Hydraulics supplies hydraulic equipment you can rely on.
Calculating force, speed, pressure, power, and efficiency in hydraulic applications.
How do you calculate actuator speed?
Actuator speed is determined by flow rate and cross-sectional area: Speed = Flow rate ÷ Area Flow rate is the volume of fluid delivered (in L/min or GPM). Area is the cross-sectional area of the actuator piston: π × (diameter ÷ 2)².
How do you calculate cylinder force?
Cylinder force can be calculated using: Force = Pressure × Area Pressure is the system pressure (in psi or bar). Area is the cross-sectional area of the cylinder bore (in square inches or square centimeters). Area = π × (bore diameter ÷ 2)².
How do you calculate pressure drop across a valve?
Pressure drop can be calculated using the valve flow coefficient (Cv): Pressure Drop (ΔP) = (Flow Rate)² ÷ (Cv² × Fluid Density) Flow Rate is the fluid flow (in GPM or L/min). Cv is the valve flow coefficient. Fluid Density is the density of the hydraulic fluid.
How do you size an accumulator?
Accumulator sizing considers required flow, pressure, and pre-charge: Accumulator Volume = Flow Rate × Time ÷ Pressure This determines how much fluid must be stored to maintain system pressure.
How to convert psi to bar?
Use the conversion factor: 1 bar = 14.5 psi. To convert psi to bar, divide psi by 14.5. Example: 200 psi ÷ 14.5 = 13.79 bar.
What is pre-charge pressure in an accumulator?
Pre-charge pressure is the initial gas pressure in the accumulator before fluid enters. It helps maintain system pressure as the accumulator discharges. Typically set to 70–80% of system operating pressure.
What is specific gravity of hydraulic fluid?
Specific gravity is the ratio of hydraulic fluid density to water. A value of 1 means equal density. Less than 1 means the fluid floats; greater than 1 means it sinks.
What is torque in a hydraulic motor?
Torque is the rotational force produced based on system pressure and motor displacement: Torque = Pressure × Displacement ÷ 2π Pressure is the operating system pressure. Displacement is the volume displaced per revolution (in cubic inches or cubic centimeters).
What unit is hydraulic power measured in?
Hydraulic power is measured in horsepower (HP) or kilowatts (kW). Hydraulic horsepower can be calculated using: HP = (Pressure (psi) × Flow rate (GPM)) ÷ 1714.
What’s the relationship between pump speed and flow?
Flow rate is directly proportional to pump speed. If pump speed doubles, flow rate doubles (assuming constant displacement). This is important when adjusting flow or selecting a pump for varying speeds.