Your cart is empty
Login / Register in for faster checkout.
Already have an account? Log in
Cart
Shop by product
Hydraulic Rotators & Links
Worm Drives Units & Rotary Manifolds
Excavator & Crane Attachments
Forestry Attachments
Rail Attachments
Demolition Attachments
Subsea Attachments
Tractor Attachments
Wireless Weigh Scales
Timber Processing
Mining & Quarry
Directional Control Valves
Line Mounted Valves
Hydraulic Cylinders
Hydraulic Pumps
Hydraulic Motors
Power Packs
PTO Equipment
Remote Controls
Worm Drives & Rotary Manifolds
Oils & Lubricants
Hydraulic Oil Tanks
Stabiliser Pads & Storage Cages
All Other Equipment
CETOP 3 Coil -24VDC Coil (23mm Bore x 50mm long)
Key Features
Scanreco Decal Set (45676)
CETOP 3 Coil - 12VDC, (23mm Bore x 50mm long)
CETOP 3 Coil – 220VAC-50HZ (23mm Bore x 50mm long)
Sales Director
I began my engineering career at Stockport College in around 2005, first completing a National Diploma in Electrical Engineering, followed by a Higher National Diploma in Mechanical Engineering. I then progressed to the University of Salford, where I earned a BEng (Hons) degree in Mechanical Engineering.
After graduating, I started my professional career with Approved Hydraulics. I initially gained a combination of hands-on workshop experience and telephone-based sales experience. In later years, I moved into a full-time sales role and led the new crane and excavator attachments department that the company had recently established.
GASKET ZF (0,5MM) - 4 BOLT
12VDC Coil For Z80 Valve 22mm Hole x 54mm Long
Din Connector plug 3 Pole + Earth - IP65 - Max 240 VAC - 10A
127mm 2 bolt level gauge with temp M12
3/8 BSP male/ female extension (pair 62mm long)
Standard DIN Hirschmann Connector Plug - Black
12vDC Coil For Z50 valve 16.3mm Hole x 50mm Long
Restrictor 0.7mm 3/8 - 3/8 Male / Male
3/4" BSP Return Filter Housing
Electrical plug for 12/24VDC coils EP3/4 kits
24V DC Coil-22W-13mm hole-39mm long for 45 - 50L - 80L-90L-100L-150L Unloader Valve
Support for ABER ABCD Cab Control Units
3/8" Hose Burst Valve Cartridge
24VDC Coil For Z80 Valve 22mm Hole x 54mm Long
Grease Nipple 1/8 BSP
3/8 Banjo Bolt c/w 2 x washers (50mm long )
Stabiliser Leg Ram Cylinder Assembly 70 x 50 x 270 Stroke (incl Pilot Operated Check Valve)
Atlas Crane Control Lever
Maxma - MR Hydraulic Motor 200cc 25mm Parallel Key Shaft
24vDC Coil For HP-50 Monoblock Valve 24mm Dia Hole x 104mm Long
Discover quality newly added products from Approved Hydraulics, trusted by professionals across construction, transport, forestry, agriculture and industrial sectors. Built for demanding working environments, our range offers dependable performance, durable construction and trusted reliability. Whether you are replacing existing parts or specifying components for a new build, our experienced team can help you find the right product. With fast UK delivery and expert technical support, Approved Hydraulics supplies hydraulic equipment you can rely on.
Calculating force, speed, pressure, power, and efficiency in hydraulic applications.
How do you calculate actuator speed?
Actuator speed is determined by flow rate and cross-sectional area: Speed = Flow rate ÷ Area Flow rate is the volume of fluid delivered (in L/min or GPM). Area is the cross-sectional area of the actuator piston: π × (diameter ÷ 2)².
How do you calculate cylinder force?
Cylinder force can be calculated using: Force = Pressure × Area Pressure is the system pressure (in psi or bar). Area is the cross-sectional area of the cylinder bore (in square inches or square centimeters). Area = π × (bore diameter ÷ 2)².
How do you calculate pressure drop across a valve?
Pressure drop can be calculated using the valve flow coefficient (Cv): Pressure Drop (ΔP) = (Flow Rate)² ÷ (Cv² × Fluid Density) Flow Rate is the fluid flow (in GPM or L/min). Cv is the valve flow coefficient. Fluid Density is the density of the hydraulic fluid.
How do you size an accumulator?
Accumulator sizing considers required flow, pressure, and pre-charge: Accumulator Volume = Flow Rate × Time ÷ Pressure This determines how much fluid must be stored to maintain system pressure.
How to convert psi to bar?
Use the conversion factor: 1 bar = 14.5 psi. To convert psi to bar, divide psi by 14.5. Example: 200 psi ÷ 14.5 = 13.79 bar.
What is pre-charge pressure in an accumulator?
Pre-charge pressure is the initial gas pressure in the accumulator before fluid enters. It helps maintain system pressure as the accumulator discharges. Typically set to 70–80% of system operating pressure.
What is specific gravity of hydraulic fluid?
Specific gravity is the ratio of hydraulic fluid density to water. A value of 1 means equal density. Less than 1 means the fluid floats; greater than 1 means it sinks.
What is torque in a hydraulic motor?
Torque is the rotational force produced based on system pressure and motor displacement: Torque = Pressure × Displacement ÷ 2π Pressure is the operating system pressure. Displacement is the volume displaced per revolution (in cubic inches or cubic centimeters).
What unit is hydraulic power measured in?
Hydraulic power is measured in horsepower (HP) or kilowatts (kW). Hydraulic horsepower can be calculated using: HP = (Pressure (psi) × Flow rate (GPM)) ÷ 1714.
What’s the relationship between pump speed and flow?
Flow rate is directly proportional to pump speed. If pump speed doubles, flow rate doubles (assuming constant displacement). This is important when adjusting flow or selecting a pump for varying speeds.